Skip to content

How it works

Engineered to be evaluated.

The full technical line for the people who sign off: five subsystems, cold-climate free cooling, sovereignty as concrete controls, and a deployment path that compresses years into 8–12 weeks. Numbers are design or target values unless measured.

Five subsystems

What's inside the base.

01

Structure

A standardized, zoned container shell — factory-prefabricated, craned into place, and built around standardized interfaces for repeatable deployment.

02

Liquid cooling

Cold-plate liquid cooling with CDU and dry cooler, augmented by cold-climate free cooling. Design PUE ≤ 1.15; measured figures available on request.

03

Power and distribution

Power-first siting, including self-generation where the grid can't reach. Distribution sized for 40–60 kW per rack.

04

Spine-Leaf network

A Spine-Leaf fabric for high east-west bandwidth, with isolated out-of-band management for safe remote operations.

05

Monitoring and the platform

The Mash Compute platform unifies DCIM, BMS and EMS, multi-tenancy, alerting, billing, and 24/7 remote operations across every base.

Efficiency

Cold-climate free cooling and PUE.

Canada's climate is an asset. Free cooling draws on cold ambient air to shed heat for much of the year, and cold-plate liquid cooling carries heat away at the source — together targeting a design PUE of ≤ 1.15. Measured figures are available on request.

Design PUE≤ 1.15
Cold supplyWarm return

Sovereignty and compliance

Compliance is sovereignty.

We're building to recognized standards and showing the controls behind them — targeted and in progress, stated honestly.

Targeted standards

  • PSPC Protected B
  • ISO 27001
  • UL 2755
  • CSA + fire safety
  • Canadian data residency

Concrete controls

  • Network tiering and zero-trust segmentation
  • Role-based access control (RBAC)
  • Audit logging across the stack
  • TLS in transit and encryption at rest
  • Backup and disaster recovery

Deployment

Years to 8–12 weeks.

A repeatable path from site survey to assured operations.

  1. 01

    Survey

    Assess the site: power, ground, access, and connectivity.

  2. 02

    Mobilize

    Transport, crane, position, wire, and commission the prefabricated base.

  3. 03

    Integrate

    Bring up the network, the GPUs, and the Mash Compute platform.

  4. 04

    Assure

    Validate cooling, power, and availability targets, then hand over to 24/7 remote operations.

Want to put it in front of your evaluators?

We'll share reference configurations and the control set behind them.